Welcome to OStack Knowledge Sharing Community for programmer and developer-Open, Learning and Share
Welcome To Ask or Share your Answers For Others

Categories

0 votes
1.1k views
in Technique[技术] by (71.8m points)

vbscript - Error ASP 0177: 8007007e CreateObject fails for COM DLL

We have been trying to install a COM DLL on a new server. The interface is Classic ASP. The Map Connector DLL seems to be the problem but that is as far as I am able to get.

We are unable to get the pages served by IIS to give anything other than a 500 error.

When tracing the ASP:

127.  -ASP_SCRIPT_TRACE_COM_CALL_END 


FilePath
C:INETPUBWWWROOTMILERGLOBAL.ASA 

LineNumber
6 

CurrentStatement
set g_pcmsrv=Server.CreateObject("PCMServer.PCMServer") 

SizeOfStatement
55 


0 ms


128.  -ASP_LOG_ERROR 


LineNumber
6 

ErrorCode
ASP 0177 : 8007007e 

Description
Server.CreateObject Failed

The DLL is PCMSRV32.DLL in c:windows

GLOBAL.ASA:

Sub Application_OnStart


set g_pcmsrv=Server.CreateObject("PCMServer.PCMServer")
set application("g_pcmsrv") = g_pcmsrv

set g_pcmmapmgr=Server.CreateObject("Pcmgole.PCMMapMgr")
set application("g_pcmmapmgr") = g_pcmmapmgr


End Sub

Sub Session_OnStart
set Session("currentTrip") = application("g_pcmsrv").NewTrip("NA")
set Session("map") = application("g_pcmmapmgr").createMap()
End Sub

Sub Session_OnEnd
set Session("currentTrip") = Nothing
set Session("map") = Nothing
End Sub

Sub Application_Onend
Set application("g_pcmsrv")=Nothing
Set application("g_pcmmapmgr")=Nothing
End Sub
Question&Answers:os

与恶龙缠斗过久,自身亦成为恶龙;凝视深渊过久,深渊将回以凝视…
Welcome To Ask or Share your Answers For Others

1 Answer

0 votes
by (71.8m points)

The advice below relates to both Server.CreateObject and CreateObject use in

The Web Server sections are specific to but still worth reading.


What Causes This error?

Server.CreateObject Failed

is caused most commonly when Web Applications are moved from one Web Server to another without an understanding of external COM components that are in use and registered with the Web server.

From PRB: Server.CreateObject Returns HTTP 500.100 or ASP 0177 Error (0x8007007E)

This error occurs when you attempt to use the Server.CreateObject method to instantiate an object that is not registered on the local system.

Identifying the Source of the Error

If you are using COM components inside a ASP Web application you will see a line like this

set g_pcmsrv=Server.CreateObject("PCMServer.PCMServer") 

Usually the error will point to the Set line which makes identifying the cause easier (luckily you have some nice trace code in place so it's even better).

What If You Don't Know Where the DLL Is Located?

Note: Please be careful when accessing the Windows Registry as it is very easier to inadvertently make changes that have serious consequences for the Operating System and in extreme cases will require a system restore or re-install / repair.

The string inside the CreateObject method is known as a ProgId and is used as an identifier to a key inside the Windows Registry that can be found inside the

Note: Windows Registry can be browsed in most versions of Windows using the regedit.exe also known as the Registry Editor. Be very careful when using this tool to browse the Windows Registry.

HKEY_CLASSES_ROOT

and by extension

HKEY_LOCAL_MACHINEClasses

Whenever the ASP processor encounters a ProgId it attempts to talk to the Windows Registry and find a corresponding key that denotes the location of the registered COM accessible DLL.

HKEY_CLASSES_ROOTPCMServer.PCMServer

A common approach to this is the key contains a subkey called CLSID which points to the Class GUID for the associated registered DLL. Once the GUID key is located in the

HKEY_CLASSES_ROOTCLSID

hive it can be used to find the location by looking in the subkey

HKEY_CLASSES_ROOTCLSID{GUID from CLSID}InprocServer32

where the location will be stored in the (default) value.

Example Using the ProgId - Scripting.FileSystemObject

  1. Locate Scripting.FileSystemObject subkey in HKEY_CLASSES_ROOT

    HKEY_CLASSES_ROOTScripting.FilesystemObject
    
  2. Identify GUID from subkey CLSID

    HKEY_CLASSES_ROOTScripting.FilesystemObjectCLSID
    
    (default) - "{0D43FE01-F093-11CF-8940-00A0C9054228}"  
    
  3. Use GUID to find registered DLL subkey in HKEY_CLASSES_ROOTCLSID

    HKEY_CLASSES_ROOTCLSID{0D43FE01-F093-11CF-8940-00A0C9054228}
    
  4. Check subkey InprocServer32 (default) value for the DLL location

    HKEY_CLASSES_ROOTCLSID{0D43FE01-F093-11CF-8940-00A0C9054228}InprocServer32
    
    (default) - "C:WindowsSystem32scrrun.dll"
    

No ProgId for PCMServer.PCMServer in the Registry?

If you cannot find the corresponding ProgId in the registry it is likely due to one of two reasons we will elaborate on here.

  1. The DLL is not registered.
  2. The DLL is registered in the wrong area.

How to register COM DLL with Windows

COM DLLs can be registered and have the corresponding Registry entries created by running the regsvr32.exe tool from the Windows Command Prompt using elevated permissions (this varies from version to version of Windows).

Before we continue though the architecture of both the Operating System and the mode used by the ASP Web application are very important.

Most newer hardware is 64 Bit this creates a conundrum in Windows as it now has to support newer 64 bit architecture and still maintain support for 32 bit architecture. The solution Microsoft came up with was to split the OS in two, so we have 64 bit elements and 32 bit elements. The main OS programs are broken down into two folders (only on 64 bit OS because a 32 Bit OS doesn't have to contend with 64 Bit, even if the hardware is capable of it).

Note: On 32 Bit only systems just use the 64 Bit locations for both System Files and the Windows Registry.

On a 64 Bit OS the System Programs are located in

  1. For 64 Bit programs

    %SystemRoot%System32
    
  2. For 32 Bit programs

    %SystemRoot%SysWOW64
    

This is also applies to the Windows Registry

  1. 64 Bit

    HKEY_CLASSES_ROOT
    
  2. 32 Bit

    HKEY_CLASSES_ROOTWow6432Node
    

So for example on a 64 Bit version of Windows, the following command will register the PCMSRV32.DLL in the 32 Bit Registry and create the associated COM DLL registry keys.

C:WindowsSysWOW64>regsvr32 "C:WindowsPCMSRV32.DLL"

IIS Application Pool

As everything begins to support 64 Bit including IIS you still need to be able to support legacy applications that only support 32 Bit COM, so IIS introduced in IIS 6.0 (starting with Windows Server 2003, Service Pack 1) under the Application Pool settings the configurable property Enabled32BitAppOnWin64 which allows the Application Pool to run in 32 Bit mode on 64 Bit versions of Windows.

With this in mind before you register the COM DLL to know where you should be registering it you need to know whether the Application Pool is running in 32 Bit Mode. In IIS 7.0 and above you can just check this from the Application Pool properties inside the IIS Manager application. The setting is in the Advanced Settings under the General section and is called Enable 32-Bit Applications (can also be configured in the applicationHost.config using enable32BitAppOnWin64 under the <ApplicationPools> section).

  • If Enable 32-Bit Applications is set to False

    The IIS Application Pool is running in native 64 Bit mode and any COM DLLs that need to be used by the ASP Web Application will need to support 64 Bit and be registered using the 64 Bit version of regsvr32.exe to be added into the 64 Bit registry.

    C:WindowsSystem32>regsvr32 "C:WindowsPCMSRV32.DLL"
    
  • If Enable 32-Bit Applications is set to True

    The IIS Application Pool is running in 32 Bit Mode and any COM DLLs that need to be used by the ASP Web Application will need to be 32 Bit COM DLLs and be registered using the 32 Bit version of regsvr32.exe to be added into the 32 Bit registry.

    C:WindowsSysWOW64>regsvr32 "C:WindowsPCMSRV32.DLL"
    

Registering the COM DLL Using the Wrong Version of regsvr32.exe

For example, using

C:WindowsSysWOW64>regsvr32 "C:WindowsPCMSRV32.DLL"

to register the COM DLL with the 32 Bit registry on a 64 Bit version of Windows when the IIS Application Pool is not in 32 Bit Mode will cause the ASP 500.100 Internal Server error

Server object error 'ASP 0177: 8007007e'

Server.CreateObject Failed


COM DLL Checklist

  1. What is the IIS Application Pool Advanced Setting Enable 32-Bit Applications set to, as it impacts on how you register the COM DLL?

  2. Is the DLL registered using the architecture-specific version of regsvr32.exe (if Windows version isn't 64 Bit use the default) that reflects the setting of Enable 32-Bit Applications?

  3. Does the Windows Registry contain a ProgId for the DLL in the architecture-specific location of

    HKEY_CLASSES_ROOT
    

    that reflects the setting of Enable 32-Bit Applications?

  4. Does the InprocServer32 key contain the correct location for the DLL?

  5. In the context of the account I'm using to access the COM DLL (ApplicationIdentity, LocalSystem, NetworkService etc), do I have permission to access both the physical DLL file and the registry entries?


Useful Links


与恶龙缠斗过久,自身亦成为恶龙;凝视深渊过久,深渊将回以凝视…
Welcome to OStack Knowledge Sharing Community for programmer and developer-Open, Learning and Share
Click Here to Ask a Question

...